You are here Transceivers SFP28 to SFP28-25G-DAC-0.5M2FT

SFP28 to SFP28-25G-DAC-0.5M2FT 25G SFP28 Passive Copper Twinax Cable, 0.5m (2ft)

SFP28 to SFP28-25G-DAC-0.5M2FT 25G SFP28 Passive Copper Twinax Cable, 0.5m (2ft)

This 0.5m (2ft) SFP28 to SFP28-25G-DAC-0.5M2FT compatible assembly provides 25G DAC connectivity for Generic interfaces in a SFP28 to SFP28 configuration. It is supplied as one complete cable, with specifications and installation guidance that help high-density racks balance reach, connector access and airflow while retaining the exact OEM reference required by the host.

OEM Part Number: SFP28 to SFP28-25G-DAC-0.5M2FTHT Part Number: SFP28 to SFP28-25G-DAC-0.5M2FT

Product Highlights

  • HT-manufactured DAC assembly in 0.5m (2ft)
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 0.5m (2ft), SFP28 to SFP28-25G-DAC-0.5M2FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 21mm

Specifications

HT Part NumberSFP28 to SFP28-25G-DAC-0.5M2FT
ManufacturerHT
Connector TypeSFP28 to SFP28
Max. Data Rate25Gbps
Cable TypePassive Twinax
Cable Length0.5m (1.64ft)
MediaCopper
Wire AWG30AWG
Minimum Bend Radius21mm
Power Consumption≤0.5W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
Application25G Ethernet, Data Center, 5G Wireless
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP28 to SFP28-25G-DAC-0.5M2FT; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Quantity and any labeling instructions should be attached specifically to SFP28 to SFP28-25G-DAC-0.5M2FT.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.