Juniper Networks SFP-25G-DAC-50CM Compatible 25G SFP28 Passive Copper Twinax Cable, 0.5m (2ft)

For densely populated equipment, the fixed 0.5m (2ft) version of Juniper Networks SFP-25G-DAC-50CM offers a clearly defined 25G link without separate optical modules or patch cords. The DAC assembly uses SFP28 to SFP28; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.
OEM Part Number: SFP-25G-DAC-50CMHT Part Number: SFP-25G-DAC-50CM
Product Highlights
- Compatible alternative to Juniper Networks SFP-25G-DAC-50CM
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 0.5m (2ft), SFP-25G-DAC-50CM
- Cable construction: Passive Twinax
- Conductor specification: 30AWG
- Maximum power consumption: ≤0.5W
- Minimum bend radius: 21mm
Specifications
| HT Part Number | SFP-25G-DAC-50CM |
|---|---|
| Juniper Networks Compatible | SFP-25G-DAC-50CM |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max. Data Rate | 25Gbps |
| Cable Type | Passive Twinax |
| Cable Length | 0.5m (1.64ft) |
| Media | Copper |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 21mm |
| Power Consumption | ≤0.5W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Power Supply | 3.3V |
| Application | 25G Ethernet, Data Center, 5G Wireless |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
Juniper Deployment Reference
Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 21mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Network and Protocol Considerations
The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing SFP-25G-DAC-50CM; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
Position Within the Length Range
SFP-25G-DAC-50CM is the shortest of 8 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is JNP-SFP-25G-DAC-1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
High-Density Rack Integration
In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 21mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).
Power and Thermal Planning
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Quality Assurance and Packaging
Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Neutral packaging and customer-specific packing documentation are available on request.
Ordering Information
Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Juniper Networks Compatibility and Factory Testing
The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Juniper Networks cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks SFP-25G-DAC-50CM.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, with production quantities confirmed at order stage. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.