Custom Simplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Custom Simplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This is the configured-to-order simplex armored platform: a single OS2 9/125µm G.657.A1 fiber inside a helical stainless steel tube, terminated with any mix of LC, SC, FC, ST or LSH connectors in UPC or APC polish, under a riser (OFCR), LSZH or plenum (OFNP) jacket in blue, black or white. It is the build for BiDi links, monitoring taps, test access and every other single-fiber application that stock leads do not attempt to quite match.

Product Highlights

  • Any length to order; standard range 1m to 30m stocked
  • Simplex OS2 9/125µm, built to the stated configuration
  • LC, SC, FC, ST or LSH connectors in any end-to-end mix
  • UPC or APC polish per end, return loss to 60/65dB class
  • Riser (OFCR), LSZH or plenum (OFNP) jacket, blue/black/white
  • Helical stainless steel armor, 120/225N tensile rating

Specifications

Connector TypeLC / SC / FC / ST / LSH, any end-to-end combination
Polish TypeUPC or APC per end
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
PolarityA (Tx) to B (Rx)
Jacket ColorBlue / Black / White
Cable Outside Diameter (OD)3.0mm
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Flame RatingRiser (OFCR) / LSZH / Plenum (OFNP)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return LossUPC ≥50dB, APC ≥60dB (LC/SC/FC/ST); LSH APC ≥65dB
Operating TemperatureOFNP: 0 to 70°C; OFCR/LSZH: -20 to 70°C
Storage Temperature-40 to 70°C (-40 to 158°F)

Simplex configurations for BiDi and monitoring

Single-fiber transmission has become the default in access and increasingly in the data center: BiDi optics, WDM systems, monitoring taps and test access ports all light exactly one strand. A customized simplex cord matches that reality precisely, including hybrid builds such as LC UPC toward the transceiver and SC APC toward the distribution plant.

Connector and polish options

LC, SC, FC, ST and LSH bodies are all in the program, with UPC or APC polish chosen per end. That covers the awkward one-offs that stall projects: a FC-equipped OTDR launch lead, an ST legacy panel, an LSH carrier frame, or an APC plant that must meet UPC equipment. Each combination is terminated and tested as a single product.

Jacket, color and pathway

The jacket rating follows the building zone: riser (OFCR) for general and vertical pathways, LSZH for occupied public spaces, plenum (OFNP) for air-handling space. Blue is the standard single-mode color; black and white serve color-coded administration schemes or discreet routing in finished interiors. In Singapore facilities, this check should form part of the rack-access and acceptance review.

Test leads and launch cords

Customized simplex armored builds are frequently ordered as OTDR launch and receive leads, reference leads for loss test sets, and lab jumpers that get connected and disconnected all day. The armored tube protects the reference-grade termination from the handling that destroys ordinary lab leads, and the polish and connector may also be matched exactly to the instrument and the plant under test.

Access-network repairs and restoration

Simplex armored customs are a practical restoration kit: when a drop tail or frame jumper is damaged, a hybrid replacement may also be built to the specific failed combination and shipped without waiting for a distributor to stock the oddball. Keeping the failed connector types, polish and length in the trouble report is all the factory needs to review the build, which turns a multi-day sourcing problem into a single enquiry.

Length choices and custom production

Standard cable lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft). Since every cord is built to order, any length between or beyond these sizes may also be produced, which is how most access tails and test leads are actually specified.

Quality assurance and factory testing

Customized simplex leads are verified to the corresponding limits as the stock range: 0.3dB insertion loss ceiling and polish-proper return loss measured on each completed assembly. APC ends are angle-verified, all ferrules are geometry-checked, and the tested figures ship with the batch documentation.

Quotation and Factory Support

Send this connector interface types and polish per end, the jacket rating, color and length. The factory confirms the manufacturable specification and lead time with the quotation; photos or drawings of the installed interfaces help avoid polish mismatches before manufacturing begins. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.