SFP28 to SFP28-25G-DAC-4M13FT 25G SFP28 Passive Copper Twinax Cable, 4m (13ft)

For densely populated equipment, the fixed 4m (13ft) version of Generic SFP28 to SFP28-25G-DAC-4M13FT offers a clearly defined 25G link without separate optical modules or patch cords. The DAC assembly uses SFP28 to SFP28; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.
OEM Part Number: SFP28 to SFP28-25G-DAC-4M13FTHT Part Number: SFP28 to SFP28-25G-DAC-4M13FT
Product Highlights
- HT-manufactured DAC assembly in 4m (13ft)
- 25G connectivity at 25Gbps
- Interface configuration: SFP28 to SFP28
- Fixed length and part number: 4m (13ft), SFP28 to SFP28-25G-DAC-4M13FT
- Conductor specification: 26AWG
- Minimum bend radius: 28mm
Specifications
| HT Part Number | SFP28 to SFP28-25G-DAC-4M13FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 28mm |
| Wire AWG | 26AWG |
| Cable Length | 4m (13.12ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
| Application | 25G Ethernet, Data Center, 5G Wireless |
Cable Construction and Routing
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Length Selection and Installation Planning
The 4m (13ft) length gives SFP28 to SFP28-25G-DAC-4M13FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
Position Within the Length Range
SFP28 to SFP28-25G-DAC-4M13FT occupies the middle of this family between SFP28 to SFP28-25G-DAC-3M10FT at 3m (10ft) and SFP28 to SFP28-25G-DAC-5M16FT at 5m (16ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
High-Density Rack Integration
In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the jacket material is PVC (OFNR).
Network and Protocol Considerations
The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Quality Assurance and Packaging
Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Standard protective packing is used by default, with project documentation arranged when requested.
Ordering Information
Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Keep SFP28 to SFP28-25G-DAC-4M13FT associated with 4m (13ft) throughout the order and receiving record.
Generic Compatibility and Factory Testing
The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Frequently Asked Questions
Is this an original equipment manufacturer cable?
No. It is manufactured by HT under our own manufacturer identity.
Does this order code cover multiple lengths?
No. SFP28 to SFP28-25G-DAC-4M13FT refers here to 4m (13ft). Every other verified length has a separate part number and page in the length list.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Shipping and Lead Time
Standard configurations normally ship within one to three working days, with production quantities confirmed at order stage. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
SFP28 to SFP28-25G-DAC-4M13FT