You are here Transceivers SFP-DD to SFP-DD-100G-DAC-2M7FT

SFP-DD to SFP-DD-100G-DAC-2M7FT 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

SFP-DD to SFP-DD-100G-DAC-2M7FT 100G SFP-DD 2 x 50G PAM4 Passive Copper Twinax Cable, 2m (7ft)

The SFP-DD to SFP-DD-100G-DAC-2M7FT cable on this page is the 2m (7ft) version for Generic hosts requiring 100G operation. Its SFP-DD to SFP-DD DAC construction reduces the connection to one factory-terminated assembly. Related lengths, brand cross-references and rack-integration notes support a precise high-density deployment.

OEM Part Number: SFP-DD to SFP-DD-100G-DAC-2M7FTHT Part Number: SFP-DD to SFP-DD-100G-DAC-2M7FT

Product Highlights

  • HT-manufactured DAC assembly in 2m (7ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to SFP-DD
  • Fixed length and part number: 2m (7ft), SFP-DD to SFP-DD-100G-DAC-2M7FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 25.2mm

Specifications

HT Part NumberSFP-DD to SFP-DD-100G-DAC-2M7FT
ManufacturerHT
Form FactorSFP-DD to SFP-DD
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length2m (7ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius25.2mm
Wire AWG28AWG
Max. Power Consumption0.1W
Modulation Format2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFP-DD MSA, SFP-DD MIS, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

SFP-DD to SFP-DD-100G-DAC-2M7FT occupies the middle of this family between SFP-DD to SFP-DD-100G-DAC-1M3FT at 1m (3ft) and SFP-DD to SFP-DD-100G-DAC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 25.2mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 25.2mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFP-DD MSA, SFP-DD MIS, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

SFP-DD to SFP-DD-100G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Keep SFP-DD to SFP-DD-100G-DAC-2M7FT associated with 2m (7ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP-DD to SFP-DD-100G-DAC-2M7FT refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.