SC UPC to SC UPC Duplex OS2, 2.0mm, ofnr Fiber Patch Cable

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This OS2 fiber patch cable carries a SC UPC interface on one end and a SC UPC interface on the other, factory terminated on OS2 glass and optically tested as a full product. The duplex zipcord structure keeps the transmit and receive strands paired in one product for fast, error-free patching.
Product Highlights
- G.657.A1 Bend Insensitive Fiber with 10mm Min. Bend Radius
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Flame-Retardant Riser (OFNR) for Vertical and Floor-to-Floor Installations
- Color-Coded Cable Jacket for Easy Identification
- Duplex Zipcord Construction Reduces Risk of Damage from Crimping
Specifications
| Connector A | SC UPC Duplex |
|---|---|
| Connector B | SC UPC Duplex |
| Fiber Count | 2 Fibers |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Flame Rating | Riser (OFNR) |
| Cable Outside Diameter (OD) | 2.0mm |
| Polarity | A (Tx) to B (Rx) |
| Cable Type | Tight-Buffered |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Connector Durability | 1000 times |
| Tensile Strength | 90/150N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB |
| Attenuation at 1310nm | ≤0.4dB/km |
| Attenuation at 1550nm | ≤0.3dB/km |
| Operating Temperature | -10 to 70°C (14 to 158℉) |
| Storage Temperature | -20 to 70°C (-4 to 158℉) |
Bend tolerance in real cabinets
Patch fields are rarely kind to fiber. Leads pathway through tight managers, sharp tray corners and crowded vertical channels. The bend-insensitive glass in this terminated assembly tolerates a 10mm fiber bend radius; consequently, a hurried routing decision during a night upkeep window will not by itself turn into a measurable penalty on the channel.
Where single-mode jumpers earn their place
Single-mode patching carries the links that leave the room: campus backbones, carrier handoffs, long runs between buildings and every wavelength-multiplexed service. The OS2 glass in this terminated assembly is the corresponding class used in the outside plant; consequently, the completed jumper will not by itself become the weak point of the link loss budget. At 1310 and 1550nm the attenuation stays a fraction of a decibel per kilometer, and this connector interface pair adds less than 0.3dB when the end faces are clean and seated.
Length Options
Standard cable lengths cover the common patching routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 7m (23ft), 10m (33ft), 15m (49ft), with custom length obtainable beyond the list. Specifying the measured pathway length keeps the slack out of the manager and the strain off these optical interfaces.
Quality Control and Testing
Each completed assembly is terminated with precision zirconia ferrule connectors and optically tested before packing: insertion loss and return loss are verified on each cable, and end-face geometry is inspected for consistent physical contact. This optical cable ships with dust caps on both connectors and the test result obtainable on ask for.
Ordering and Factory Support
Refer to this arrangement by connector pair, fiber mode and length during the request for a quotation. For configurations outside the listed options, mixed connector families, jackets, marking or project packaging, send the requirement with the enquiry and the factory will review the build before manufacturing begins. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.