SC UPC to Unterminated Fiber Pigtail, Simplex, OM3, 0.9mm

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: SC UPC to Unterminated Fiber Pigtail, OM3 glass, with a factory-polished SC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber pathway into a documented, testable port.
Product Highlights
- Bend Insensitive Fiber & 7.5mm Min. Bend Radius
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Easy-strip 900µm Tight-buffered Coating
- Color-Coded Cable Jacket for Easy Identification
- Support Both Fusion and Mechanical Splicing
Specifications
| Connector A | SC UPC Simplex |
|---|---|
| Connector B | Unterminated |
| Fiber Count | 1 Fiber |
| Fiber Grade | Bend Insensitive |
| Fiber Mode | OM3 50/125μm |
| Wavelength | 850/1300nm |
| Jacket Color | Aqua |
| Cable Jacket | PVC (Unrated) |
| Min. Bend Radius (Optical Fiber) | 7.5mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Connector Durability | 1000 Times |
| Attenuation at 850nm | 0.30dB/km |
| Attenuation at 1300nmm | 1.0dB/km |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥30dB |
| Operating Temperature | -40 to 75°C (-40 to 167℉) |
| Storage Temperature | -45 to 85°C (-49 to 185℉) |
| Connector Type | SC to Unterminated |
| Fiber Count | 1 Fiber |
| Fiber Grade | Bend Insensitive |
From raw fiber route to documented port
Every structured cabling plant ends the corresponding way: a cable arrives at a frame, and its fibers must become ports. The pigtail is the component that makes that conversion. Spliced into a tray and presented on a panel, each strand gains a connector with a known optical signature, a slot in the documentation and a place in the test record. That conversion - cable to port - is where channel quality is won or lost.
Mechanical splicing as the field fallback
Where a fusion splicer must not be treated as obtainable, mechanical splices get the channel up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse; consequently, the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports both methods keeps the version open.
Fusion splicing practice that protects the budget
A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. In Singapore facilities, this check should form part of the rack-access and acceptance review.
Choosing the fiber mode for the plant
Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve equipment rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal this optical cable plant mode - a mismatch splices poorly and performs worse.
Bend-insensitive glass in dense trays
Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the channel margin intact after the tenth tray opening, not just at commissioning.
Sparing and kit planning for termination work
Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame slot, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may also be ordered to the identical specification.
A splicing workflow that scales
Productive termination crews work to a fixed routine: mount the tray, dress this optical cable, splice the pigtails color by color, protect each joint, test each completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame slot in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - corresponding materials, corresponding sequence, corresponding pass criteria across every site.
Selecting the right pigtail for the job
Five decisions define the order: this connector interface range must correspond to the patch panel, the polish must correspond to the plant, the fiber mode must correspond to this optical cable, the structure must correspond to the pathway, and the count must correspond to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the requirement sits outside the standard configurations, the custom platforms cover the remaining combinations.
Quality Assurance and Factory Testing
Every pigtail is optically tested before packing: insertion loss and return loss are verified on each terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results obtainable on ask for.
Quotation and Factory Support
Refer to this pigtail by connector, polish, fiber mode, fiber count and structure during the request for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packaging - send the requirement with the enquiry and the factory will review the manufacturable specification. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.