You are here Transceivers QSFP56 to 2x QSFP28-200G-AOC-1M3FT

QSFP56 to 2x QSFP28-200G-AOC-1M3FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 1m (3ft)

QSFP56 to 2x QSFP28-200G-AOC-1M3FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 1m (3ft)

The QSFP56 to 2x QSFP28-200G-AOC-1M3FT cable on this page is the 1m (3ft) version for Generic hosts requiring 200G operation. Its QSFP56 to 2x QSFP28 AOC construction reduces the connection to one factory-terminated assembly. Related lengths, brand cross-references and rack-integration notes support a precise high-density deployment.

OEM Part Number: QSFP56 to 2x QSFP28-200G-AOC-1M3FTHT Part Number: QSFP56 to 2x QSFP28-200G-AOC-1M3FT

Product Highlights

  • HT-manufactured AOC assembly in 1m (3ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 2x QSFP28
  • Fixed length and part number: 1m (3ft), QSFP56 to 2x QSFP28-200G-AOC-1M3FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 5.5W(QSFP56 End)5.5W(QSFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP56 to 2x QSFP28-200G-AOC-1M3FT
ManufacturerHT
Form FactorQSFP56 to 2x QSFP28
Max. Data Rate200Gbps
Cable Length1m (3ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption5.5W(QSFP56 End)5.5W(QSFP28 Per End)
Jacket MaterialOFNP
Modulation (Electrical)QSFP56-4x 50G-PAM4 QSFP28-4x 25G-NRZ
Modulation (Optical)QSFP56-4x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
DDM/DOMSupported
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Inbuilt FECYes
ProtocolsIEEE 802.3cd-100GAUI-2, IEEE802.3bm-CAUI-4, IEEE 802.3cd, SFF-8661, SFP-8636, SFF-8636

Signal and Lane Configuration

The listed modulation format is QSFP56-4x 50G-PAM4 QSFP28-4x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 5.5W(QSFP56 End)5.5W(QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd-100GAUI-2, IEEE802.3bm-CAUI-4, IEEE 802.3cd, SFF-8661, SFP-8636, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 2x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

At 1m (3ft), QSFP56 to 2x QSFP28-200G-AOC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

QSFP56 to 2x QSFP28-200G-AOC-1M3FT is the shortest of 10 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP56 to 2x QSFP28-200G-AOC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 5.5W(QSFP56 End)5.5W(QSFP28 Per End); the jacket material is OFNP.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Keep QSFP56 to 2x QSFP28-200G-AOC-1M3FT associated with 1m (3ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.