You are here Transceivers Generic 400G AOC

QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 15m (49ft)

QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 15m (49ft)

For densely populated equipment, the fixed 15m (49ft) version of Generic QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT offers a clearly defined 400G link without separate optical modules or patch cords. The AOC assembly uses QSFP-DD to 8x 50G SFP56; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.

OEM Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FTHT Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT

Product Highlights

  • HT-manufactured AOC assembly in 15m (49ft)
  • 400G connectivity at 425Gbps (8x 53.125GGbps)
  • Interface configuration: QSFP-DD to 8x 50G SFP56
  • Fixed length and part number: 15m (49ft), QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT
  • Cable construction: OM3
  • Maximum power consumption: 10W (QSFP-DD End) 3W (SFP56 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberQSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT
ManufacturerHT
Form FactorQSFP-DD to 8x 50G SFP56
Max. Data Rate425Gbps (8x 53.125GGbps)
Cable Length15m
Cable TypeOM3
Minimum Bend Radius30mm
Max. Power Consumption10W (QSFP-DD End) 3W (SFP56 Per End)
Transmitter TypeVSCEL
Receiver TypePIN
Modulation FormatPAM4
Wavelength850nm
Jacket MaterialOFNP
BER2.4E-4
Inbuilt FECNo
Operating Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFP56 MSA, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

A 15m (49ft) run can remain tidy when its pathway and service allowance are planned together. Keep the integrated optical cable and both optical engines away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. Within this family, QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT is shorter at 10m (33ft), while QSFP-DD to 8x 50G SFP56-400G-AOC-20M66FT is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT occupies the middle of this family between QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT at 10m (33ft) and QSFP-DD to 8x 50G SFP56-400G-AOC-20M66FT at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x 50G SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. This page’s fixed configuration is 15m (49ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production quantities confirmed at order stage. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.