You are here Transceivers Generic 200G AOC

QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Active Optical Breakout Cable, 7m (23ft)

QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Active Optical Breakout Cable, 7m (23ft)

For densely populated equipment, the fixed 7m (23ft) version of Generic QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT offers a clearly defined 200G link without separate optical modules or patch cords. The AOC assembly uses QSFP-DD to 8x 25G SFP28; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.

OEM Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FTHT Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT

Product Highlights

  • HT-manufactured AOC assembly in 7m (23ft)
  • 200G connectivity at 206.24Gbps (8x 25.78Gbps)
  • Interface configuration: QSFP-DD to 8x 25G SFP28
  • Fixed length and part number: 7m (23ft), QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT
  • Cable construction: OM3
  • Maximum power consumption: QSFP-DD <4W,SFP28 <1W
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT
ManufacturerHT
Form FactorQSFP-DD to 8x 25G SFP28
Max. Data Rate206.24Gbps (8x 25.78Gbps)
Cable Length7m
Cable TypeOM3
Minimum Bend Radius30mm
Power ConsumptionQSFP-DD <4W,SFP28 <1W
Transmitter TypeVSCEL
Receiver TypePIN
Modulation FormatNRZ
BER5E-5
Inbuilt FECNo
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x 25G SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

For this 7m (23ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. Within this family, QSFP-DD to 8x 25G SFP28-200G-AOC-5M16FT is shorter at 5m (16ft), while QSFP-DD to 8x 25G SFP28-200G-AOC-10M33FT is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT occupies the middle of this family between QSFP-DD to 8x 25G SFP28-200G-AOC-5M16FT at 5m (16ft) and QSFP-DD to 8x 25G SFP28-200G-AOC-10M33FT at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the minimum bend radius is 30mm; the stated power consumption is QSFP-DD <4W,SFP28 <1W.

Power and Thermal Planning

The rated power consumption is QSFP-DD <4W,SFP28 <1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Keep QSFP-DD to 8x 25G SFP28-200G-AOC-7M23FT associated with 7m (23ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production quantities confirmed at order stage. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.