Cisco QSFP-4SFP25G-CU1M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 1m (3ft)

This 1m (3ft) QSFP-4SFP25G-CU1M compatible assembly provides 100G DAC connectivity for Cisco interfaces in a QSFP28 to SFP28 configuration. It is supplied as one complete cable, with specifications and installation guidance that help high-density racks balance reach, connector access and airflow while retaining the exact OEM reference required by the host.
OEM Part Number: QSFP-4SFP25G-CU1MHT Part Number: QSFP-4SFP25G-CU1M
Product Highlights
- Compatible alternative to Cisco QSFP-4SFP25G-CU1M
- 100G connectivity at 100Gbps
- Interface configuration: QSFP28 to SFP28
- Fixed length and part number: 1m (3ft), QSFP-4SFP25G-CU1M
- Cable construction: Passive Twinax
- Conductor specification: 30AWG
- Maximum power consumption: ≤0.125W
- Minimum bend radius: 60mm
Specifications
| HT Part Number | QSFP-4SFP25G-CU1M |
|---|---|
| Cisco Compatible | QSFP-4SFP25G-CU1M |
| Manufacturer | HT |
| Form Factor | QSFP28 to SFP28 |
| Max Data Rate | 100Gbps |
| Cable Type | Passive Twinax |
| Cable Length | 1m (3ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 60mm |
| Power Consumption | ≤0.125W |
| Power Supply | 3.3V |
| MTBF | =50 Million Hours |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| Media | Copper |
| Application | 100G to 4x 25G Ethernet, Data Centers |
| Protocols | IEEE 802.3, QSFP28 MSA, SFF-8665 |
Cisco OEM Reference
Cisco defines QSFP-4SFP25G-CUxM as a 100G QSFP to four 25G SFP passive copper breakout assembly. One end connects to a 100G QSFP port and the four branches connect to 25G interfaces on a switch or server. Correct channelization and lane mapping are essential for this HT compatible version as well.
Network and Protocol Considerations
The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.
Breakout Port Mapping
The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Passive Copper Operation
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Length Selection and Installation Planning
At 1m (3ft), QSFP-4SFP25G-CU1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
Position Within the Length Range
QSFP-4SFP25G-CU1M occupies the middle of this family between QSFP-4SFP25G-CU50CM at 0.5m (2ft) and QSFP-4SFP25G-CU1-5M at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
High-Density Rack Integration
In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).
Signal and Lane Configuration
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Power and Thermal Planning
The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Cable Construction and Routing
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Quality Assurance and Packaging
Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Neutral packaging and customer-specific packing documentation are available on request.
Ordering Information
Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
Cisco Compatibility and Factory Testing
The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Frequently Asked Questions
Is this an original Cisco cable?
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QSFP-4SFP25G-CU1M.
Are separate transceivers or patch leads required?
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Can excess cable be folded into a compact bundle?
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Will any matching connector operate at the same speed?
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Shipping and Lead Time
Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.