You are here Transceivers Generic 400G AOC

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 3m (10ft)

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 3m (10ft)

This 3m (10ft) OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT compatible assembly provides 400G AOC connectivity for Generic interfaces in a OSFP (IHS/Finned Top) to 2x QSFP56 configuration. It is supplied as one complete cable, with specifications and installation guidance that help high-density racks balance reach, connector access and airflow while retaining the exact OEM reference required by the host.

OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT

Product Highlights

  • HT-manufactured AOC assembly in 3m (10ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP56
  • Fixed length and part number: 3m (10ft), OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length3m (10ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatOSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4
Host FECPre-FEC BER 2.4E-4, Post-FEC BER 1E-12
Application400G/200G Ethernet
ProtocolsIEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636

Signal and Lane Configuration

The listed modulation format is OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT is the shortest of 6 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-5M16FT at 5m (16ft), adding 2m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G/200G Ethernet. Listed interface and protocol references include IEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-3M10FT.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.