NVIDIA/Mellanox MCP7F60-W03 Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Ethernet Active Copper Breakout Cable, 3m (10ft)

NVIDIA/Mellanox MCP7F60-W03 Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Ethernet Active Copper Breakout Cable, 3m (10ft)

For densely populated equipment, the fixed 3m (10ft) version of NVIDIA/Mellanox MCP7F60-W03 offers a clearly defined 400G link without separate optical modules or patch cords. The ACC assembly uses QSFP-DD to 4x QSFP56; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.

OEM Part Number: MCP7F60-W03HT Part Number: MCP7F60-W03

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCP7F60-W03
  • 400G connectivity at 400Gb/s
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 3m (10ft), MCP7F60-W03
  • Cable construction: Active Twinax
  • Conductor specification: 30 AWG
  • Maximum power consumption: <0.1W
  • Minimum bend radius: 70mm

Specifications

HT Part NumberMCP7F60-W03
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max Data Rate400Gb/s
Cable Length3m
Cable TypeActive Twinax
Minimum Bend Radius70mm
Wire AWG30 AWG
Jacket MaterialPVC
Power Consumption<0.1W
Modulation FormatPAM4
Inbuilt FECNo
Operating Temperature Range0 to 70°C (32 to 158°F)
Inbuilt FECQSFP-DD MSASFF-8679SFF-8636

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 30 AWG; the minimum bend radius is 70mm; the stated power consumption is <0.1W; the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is <0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30 AWG conductors, PVC jacket, minimum bend radius 70mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

MCP7F60-W03 is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCP7F60-W04 at 4m (13ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Neutral packaging and customer-specific packing documentation are available on request.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Quantity and any labeling instructions should be attached specifically to MCP7F60-W03.

NVIDIA/Mellanox Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7F60-W03.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.