LC UPC to LC UPC Duplex OS2 OFNR 24F Indoor Breakout Cable

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This pre-terminated breakout cable delivers a full 24-fiber indoor channel in one factory-built product: an OS2 single-mode trunk on a riser (OFNR) jacket opens into duplex LC UPC legs at each end, every leg optically tested before packing. It replaces a full day of field termination with a single plug-in deployment.
Product Highlights
- Riser (OFNR) Flame-retardant Jacket
- Precision Zirconia Ferrule Connectors Ensure Low Loss
- Duplex Clip Prevents the Fiber from Rotating and Maintains the Polarity
- G.657.A1 Bend Insensitive Fiber & 10mm Min. Bend Radius
- Optical Testing Ensures Network Performance
Specifications
| Connector Type | LC Duplex |
|---|---|
| Polish Type | UPC |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Fiber Count | 24 Fibers |
| Cable Jacket | Riser (OFNR) |
| Fiber Grade | G.657.A1 |
| Minimum Bend Radius | 20/10D (Dynamic/Static) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB |
| Attenuation at 1310nm | 0.36 dB/km |
| Attenuation at 1550nm | 0.22 dB/km |
| Breakout Outside Diameter (OD) | 2.0mm |
| Trunk Outside Diameter (OD) | 15.0-16.0mm |
| Breakout Type | 0.5m Equal Breakout |
| Polarity (Duplex) | A (Tx) to B (Rx) |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -20 to 70°C (-4 to 158°F) |
Bend-insensitive glass in real pathways
Backbone routes turn through tight tray corners, congested risers and crowded vertical channels. The G.657.A1 bend-insensitive fiber in this terminated assembly tolerates a 10mm fiber bend radius; consequently, a hurried routing decision during a night upkeep window will not by itself turn into a measurable penalty on the channel. The glass remains fully compatible with the G.652.D plant it connects to.
Single-mode trunks for building and campus backbones
A pre-terminated OS2 trunk carries the links that leave the room: riser spans between floors, campus backbones between buildings and every wavelength-multiplexed service in between. The glass is the corresponding class used in the outside plant; consequently, this optical assembly will not by itself become the weak point of the link loss budget. At 1310 and 1550nm the attenuation stays a fraction of a decibel per kilometer, and each factory-polished connector adds less than 0.3dB when the end faces are clean and seated.
A complete 24-fiber link in one assembly
Twenty-four fibers is the practical size for a row feed or a floor distribution channel: ample lanes for a full panel with spares, still light ample for two field staff to pathway without mechanical help. Factory termination means every one of the 48 connector end faces is polished, inspected and tested before this optical cable ships, a level of consistency that field termination on a ladder rarely reaches.
Duplex legs for duplex optics
The legs are built as duplex pairs for the reason that the optics they serve are duplex: transmit and receive travel collectively from trunk to port. Polarity is fixed at the factory and verified before packing; consequently, the installer dresses each pair into its port without a second thought about crossover.
Riser jacket for the vertical route
The riser (OFNR) jacket is the rating that lets this terminated assembly run vertically between floors without a conduit of its own. The tight-buffered structure inside keeps each fiber individually protected; consequently, the backbone assembly tolerates the handling of a riser pull and the dressing inside the floor distributor. For routes that leave the riser-rated pathway, the custom versions of this range carry LSZH and plenum options.
From row feed to floor distribution
The natural homes of a 24-fiber duplex-leg trunk are the feeds that terminate as ports: a row of twelve duplex server or switch links, a floor distributor feeding twelve work-zone outlets, or a building entrance splitter shelf. In each case the arithmetic is the corresponding - one pull, one dressing operation, twelve tested duplex links - and the alternative is twelve distinct leads with twelve times the pathway fill and twelve times the marking effort.
Planning a trunk route
Because a multi-fiber trunk is planned once and existing once, the planning deserves the hour it takes. Measure the pathway through the actual containment, note the bend space at both connector interfaces, and decide which end gets pulled. State the pulling eye requirement with the order if the pathway is long or congested. At the far end, leave the dressing slack the patch panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed before manufacturing begins.
Available Fiber Counts
This structure is built with 24 Fibers per trunk, terminated and tested as a full product.
Length Choices and Custom Production
Standard cable lengths cover the common routes: 2m (7ft), 10m (33ft), with custom length obtainable beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured pathway length keeps the slack out of the tray and the strain off these optical interfaces.
Quality Assurance and Factory Testing
Every trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on each fiber, and end-face geometry is inspected for consistent physical contact. This optical assembly ships with dust caps on each optical connector and the test results obtainable on ask for.
Quotation and Factory Support
Refer to this arrangement by fiber mode, fiber count, connector pair, breakout geometry and length during the request for a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, marking or project packaging - send the requirement with the enquiry and the factory will review the build before manufacturing begins. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.
10/100BASE-T SFP