LC UPC to SC APC Duplex Armored Fiber Patch Cable, OS2, LSZH

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This duplex armored patch cable pairs flat-polished LC UPC connectors on one end with angled SC APC connectors on the other, on OS2 9/125µm single-mode fiber inside a helical stainless steel tube and a low smoke zero halogen jacket. It is built for carrier and access installations where LC-equipped optics must land on APC-terminated plant inside buildings that document LSZH cabling throughout.
Product Highlights
- Stock lengths 1m to 30m; custom lengths and jackets on request
- LC UPC to SC APC hybrid duplex, OS2 9/125µm single mode
- LSZH jacket: low smoke, zero halogen in a fire
- 8° APC polish on the plant end for ≥60dB-class return performance
- Helical stainless steel armor against crush, impact and rodents
- G.657.A1 bend-insensitive fiber, 10/5D bend radius
Specifications
| Connector Type | LC to SC |
|---|---|
| Polish Type | UPC to APC |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | Duplex |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Cable Outside Diameter (OD) | 3.0mm |
| Flame Rating | LSZH (Low Smoke Zero Halogen) |
| Construction Type | Single Armored, Stainless Steel Tube |
| Tensile Strength | 120/225N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB (UPC) / ≥60dB (APC) |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
| Storage Temperature | -40 to 70°C (-40 to 158°F) |
Duplex hybrid with APC on the plant end
PON and carrier access plant is terminated with angled APC connectors to keep reflections out of the arrangement; concurrently, the optics that feed it increasingly ship with LC ports. This cord bridges the two in a single tested duplex product: LC UPC toward the active hardware, green-bodied SC APC toward the frame, with no adapter pair adding loss in the middle.
LSZH plus mixed polish for carrier access spaces
Central offices, metro PoPs and in-building access rooms increasingly fall under the corresponding low smoke zero halogen rules as public buildings. This cord satisfies the jacket specification and the reflection specification at once; consequently, the compliance conversation will not by itself force a compromise on either the jacket or the polish.
Armored for plant that gets worked on
Access frames and splitter cabinets are worked on constantly, and leads there are reseated, swung aside and redressed for years. The helical steel tube inside the LSZH jacket keeps the fibers safe through that service life, and the 3.0mm build still dresses through standard frame managers.
PON distribution inside buildings
In-building PON distribution concentrates at splitter cabinets on each floor or zone, and those cabinets sit in corridors and service rooms where LSZH is specified. This cord patches LC-based OLT or test ports to the APC splitter frame within the corresponding jacket policy as the rest of the floor. The armored build tolerates the constant re-dressing that splitter cabinets see as subscribers are added.
Length choices and custom production
Standard cable lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Lengths built to order beyond this range are manufactured to order. In carrier rooms the frame slot is fixed in the records; consequently, ordering to the documented pathway length keeps the slack storage inside design limits. Specifying the specific pathway length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.
Quality assurance and factory testing
Each completed assembly is terminated with precision zirconia ferrules; the APC end is angle-verified and the UPC end geometry-checked. Insertion loss and return loss are measured through the finished duplex cord before packing; consequently, the 0.3dB insertion ceiling and the 50/60dB return figures are tested figures on the delivered product.
Quotation and Factory Support
Use against the LC UPC to SC APC OS2 LSZH armored range with the pathway length stated and the LSZH requirement referenced. Other hybrid combinations, including simplex versions, are obtainable in the corresponding jacket arrangement through the custom armored program. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.