You are here Transceivers JNP-100G-2X50G-5M

Juniper Networks JNP-100G-2X50G-5M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 5m(16ft)

Juniper Networks JNP-100G-2X50G-5M Compatible 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 5m(16ft)

For densely populated equipment, the fixed 5m(16ft) version of Juniper Networks JNP-100G-2X50G-5M offers a clearly defined 100G link without separate optical modules or patch cords. The DAC assembly uses QSFP28 to 2x SFP28; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.

OEM Part Number: JNP-100G-2X50G-5MHT Part Number: JNP-100G-2X50G-5M

Product Highlights

  • Compatible alternative to Juniper Networks JNP-100G-2X50G-5M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 2x SFP28
  • Fixed length and part number: 5m(16ft), JNP-100G-2X50G-5M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.5W
  • Minimum bend radius: 10D/5D (Dynamic/Static)

Specifications

HT Part NumberJNP-100G-2X50G-5M
Juniper Networks CompatibleJNP-100G-2X50G-5M
ManufacturerHT
Form FactorQSFP28 to 2x SFP28
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Breakout DAC
Cable Length0.5m
Jacket MaterialPVC (OFNR)
Minimum Bend Radius10D/5D (Dynamic/Static)
Wire AWG26AWG
Max. Power Consumption0.5W
Modulation FormatQSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ
Commercial Temperature Range0-70℃(32 to 158°F)
Application100G/50G Ethernet, 128G Fibre Channel
ProtocolsIEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 10D/5D (Dynamic/Static). These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G/50G Ethernet, 128G Fibre Channel. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFP-8665, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 2x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 5m(16ft) length gives JNP-100G-2X50G-5M more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.

Position Within the Length Range

JNP-100G-2X50G-5M is the longest of 6 verified length options in this family. Compared with JNP-100G-2X50G-4M at 4m(13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 10D/5D (Dynamic/Static); the stated power consumption is 0.5W; the jacket material is PVC (OFNR).

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Keep JNP-100G-2X50G-5M associated with 5m(16ft) throughout the order and receiving record.

Juniper Networks Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks JNP-100G-2X50G-5M.

Does this order code cover multiple lengths?

No. JNP-100G-2X50G-5M refers here to 5m(16ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.