Singapore Fiber Optic Supplier

You are here Transceivers 10/100BASE-T SFP

Custom LC/SC Simplex FTTA Outdoor Patch Cable, OS2, 7.0mm LSZH

Custom LC/SC Simplex FTTA Outdoor Patch Cable, OS2, 7.0mm LSZH

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. The custom simplex FTTA program builds the single-fiber outdoor base station jumper to the specific arrangement of the channel: LC or SC connectors in any mix, the measured pathway length, and an armored branch length matched to the exposed section at each end. It serves the bidirectional and single-fiber optics increasingly used on radio units, where one strand carries both directions of traffic. The platform is the proven FTTA outdoor structure: one OS2 9/125µm single-mode fiber of Corning G.657.A1 glass in a 7.0mm LSZH jacket with helical steel armored protection over the tails.

Product Highlights

  • Any project length manufactured to order
  • Simplex OS2 9/125µm single mode for BiDi links
  • LC, SC and mixed LC/SC combinations to order
  • Corning G.657.A1 bend-insensitive fiber, 20/10D bend radius
  • Armored branch length matched to the exposed section
  • 7.0mm LSZH UV-stabilized outdoor jacket

Specifications

Connector TypeLC/SC, mix to order
Polish TypeUPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex / 1 Fiber
Fiber GradeCorning G.657.A1
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Attenuation at 1310nm≤0.36dB/km
Attenuation at 1550nm≤0.22dB/km
Cable JacketLow Smoke Zero Halogen (LSZH)
Cable Diameter (Outer/Inner)7.0/2.0mm
Armored Breakout Length (End A/B)0.03/0.34/0.2m, selectable
Tensile Strength200/400N (Long/Short Term)
Crush Resistance1100/2200N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 80°C (-40 to 176°F)

A custom cord for single-fiber radio links

Because bidirectional optics place transmit and receive on one strand, the completed jumper between the baseband equipment and the radio needs exactly one fiber. Ordering that jumper as a customized simplex cord matches the hardware precisely: this connector interface at each end follows the actual port, the length follows the measured pathway, and nothing is left over. Compared with adapting a duplex cord, the customized simplex build removes the parked leg, halves this connector interface count on the record, and keeps the tower deployment as light as it may also be.

Connector freedom at both ends

Radio units, enclosures and frames present LC and SC interfaces depending on vendor and generation. The customized program terminates any mix of LC and SC on the corresponding outdoor platform, polished and tested in the factory. A site that evolves from SC-based enclosures to LC-based radios is served by one cord with LC on one end and SC on the other, with no adaptors in the optical channel and no extra mated pair in the link budget.

Outdoor mechanics unchanged

The custom cord keeps the full outdoor rating of the standard FTTA range: 200/400N long and short-term tensile strength for pulling and vertical hanging, 1100/2200N crush resistance, helical steel armored branches over the exposed tails, and an operating range from -20 to 70 degrees Celsius. The G.657.A1 fiber holds attenuation stable at the 10D static bends that appear inside congested enclosures and radio shrouds.

Repeatability across the rollout

For operators deploying the corresponding radio arrangement across numerous sites, the custom cord is specified once and repeated exactly: connector mix, length, armored branch and marking. Every site receives the identical product, commissioning follows the corresponding steps, and the spares holding stays minimal for the reason that one recorded arrangement covers the whole fleet.

Length choices and custom production

State the measured pathway length with the enquiry, including the tray channel and working slack at both connector interfaces; the factory builds to that figure and confirms the manufacturable specification before manufacturing begins.

Quality assurance and factory testing

Each custom simplex cord is terminated with precision zirconia ferrule connectors and optically tested as a full product: insertion loss is verified against the 0.3dB ceiling and return loss against the 50dB minimum. End-face geometry is inspected on each optical connector so the delivered cord may also be plugged into service without on-site rework.

Quotation and Factory Support

Send the correct connector mix, pathway length and armored branch preference with the enquiry. The factory confirms the manufacturable specification before manufacturing begins and keeps the arrangement on record for repeat orders across the rollout. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.