Custom Duplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Custom Duplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

Singapore high-density designs should assess this item together with panel access, cable routing and the complete optical loss allowance. This is the configured-to-order duplex armored platform: two fibers of OS2 9/125µm G.657.A1 glass inside a helical stainless steel tube, terminated with any combination of LC, SC, FC, ST or LSH connectors in UPC or APC polish, and jacketed in riser (OFCR), LSZH or plenum (OFNP) compound in blue, black or white. Instead of adapting a stock cord to the job, the cord is built for the job from the start. In Singapore facilities, this check should form part of the rack-access and acceptance review.

Product Highlights

  • Any length to order; standard range 1m to 30m stocked
  • Duplex OS2 9/125µm, built to the stated configuration
  • LC, SC, FC, ST or LSH connectors in any end-to-end mix
  • UPC or APC polish per end, return loss to 60/65dB class
  • Riser (OFCR), LSZH or plenum (OFNP) jacket, blue/black/white
  • Helical stainless steel armor, 120/225N tensile rating

Specifications

Connector TypeLC / SC / FC / ST / LSH, any end-to-end combination
Polish TypeUPC or APC per end
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
PolarityA (Tx) to B (Rx)
Jacket ColorBlue / Black / White
Cable Outside Diameter (OD)3.0mm
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Flame RatingRiser (OFCR) / LSZH / Plenum (OFNP)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return LossUPC ≥50dB, APC ≥60dB (LC/SC/FC/ST); LSH APC ≥65dB
Operating TemperatureOFNP: 0 to 70°C; OFCR/LSZH: -20 to 70°C
Storage Temperature-40 to 70°C (-40 to 158°F)

One platform, every connector combination

LC on the transceiver, ST on the legacy panel, FC on the test set, LSH on the carrier frame: real networks mix interfaces, and this platform terminates any of them on either end of the corresponding armored duplex cord. Hybrid builds arrive as one tested product; consequently, the MMC adapter pairs and their extra loss just never enter the channel.

Choosing the jacket: OFCR, LSZH or OFNP

The jacket follows the building zone, not the other way round. Riser (OFCR) suits vertical shafts and general pathways; LSZH is specified for occupied public spaces, tunnels and transport; plenum (OFNP) is correct where the pathway crosses air-handling space. The armor and the optical core stay the corresponding across all three; consequently, one plan may mix jackets by zone without changing the optical budget.

How custom production runs

Send this connector interface mix, polish, jacket, color and length; the factory confirms the manufacturable specification, then terminates, armors and tests the leads to that plan. Every cord in the batch is measured for insertion loss and return loss against the corresponding limits as the stock range; consequently, a customized build carries no quality penalty.

Documentation and batch consistency

Each customized build is confirmed against a written arrangement before manufacturing begins, and that arrangement becomes the reference for repeat orders. Label text, leg marking and packaging may all be added to the corresponding plan; consequently, the second batch arrives identical to the first. For projects rolled out in phases, this repeatability is generally worth more than any single specification line.

Color coding with black and white jackets

Beyond the standard blue, the duplex platform is jacketed in black or white on ask for. Black serves outdoor-adjacent and security-conscious routes where this optical cable should not draw the eye; white disappears into finished interiors, hotel corridors and office raceway. Some administrations additionally use jacket color to distinct networks or security zones on the corresponding frame. State the color with the arrangement and it is built into the jacket, not sleeved on afterward.

Length choices and custom production

Standard cable lengths are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft). Because every cord is built to order, any length in between or beyond this range may also be produced; for long runs the factory confirms reel and packaging particulars with the quotation.

Quality assurance and factory testing

Customized leads are tested to the corresponding limits as the stock range: 0.3dB insertion loss ceiling and polish-proper return loss, verified per product before packing. Ferrule geometry is checked on every end face, and APC ends are angle-verified; consequently, a mixed-polish build performs exactly as its two polishes document.

Quotation and Factory Support

Send the correct arrangement: connector types per end, polish per end, jacket rating, color and length. The factory confirms the manufacturable specification and lead time with the quotation; drawings or photos of the installed plant are welcome and speed up confirmation. Singapore and regional project orders can be reviewed for interface compatibility, packing details and delivery coordination.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.