You are here Transceivers AOC-Q-4S-100G-25M

Arista Networks AOC-Q-4S-100G-25M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 25m (82ft)

Arista Networks AOC-Q-4S-100G-25M Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 25m (82ft)

For densely populated equipment, the fixed 25m (82ft) version of Arista Networks AOC-Q-4S-100G-25M offers a clearly defined 100G link without separate optical modules or patch cords. The AOC assembly uses QSFP28 to 4x SFP28; its power, mechanical and diagnostic details are listed where supplied so port density and cable management can be assessed together.

OEM Part Number: AOC-Q-4S-100G-25MHT Part Number: AOC-Q-4S-100G-25M

Product Highlights

  • Compatible alternative to Arista Networks AOC-Q-4S-100G-25M
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4x SFP28
  • Fixed length and part number: 25m (82ft), AOC-Q-4S-100G-25M
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W (QSFP28 End)0.8W (SFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberAOC-Q-4S-100G-25M
Arista Networks CompatibleAOC-Q-4S-100G-25M
ManufacturerHT
Form FactorQSFP28 to 4x SFP28
Max. Data Rate100Gbps
Cable Length25m (82ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W (QSFP28 End)0.8W (SFP28 Per End)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP28 MSA, SFP28 MSA

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 25m (82ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, AOC-Q-4S-100G-20M is shorter at 20m (66ft), while AOC-Q-4S-100G-30M is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

AOC-Q-4S-100G-25M occupies the middle of this family between AOC-Q-4S-100G-20M at 20m (66ft) and AOC-Q-4S-100G-30M at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Neutral packaging and customer-specific packing documentation are available on request.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Quantity and any labeling instructions should be attached specifically to AOC-Q-4S-100G-25M.

Arista Networks Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original Arista Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks AOC-Q-4S-100G-25M.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. AOC-Q-4S-100G-25M refers here to 25m (82ft). Every other verified length has a separate part number and page in the length list.

Shipping and Lead Time

Available stock is normally prepared for dispatch within one to three working days, while larger production requirements are scheduled with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.