You are here Transceivers Generic 800G ACC

800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Copper Breakout Cable, 3m (10ft)

800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Copper Breakout Cable, 3m (10ft)

The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT cable on this page is the 3m (10ft) version for Generic hosts requiring 800G operation. Its 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) ACC construction reduces the connection to one factory-terminated assembly. Related lengths, brand cross-references and rack-integration notes support a precise high-density deployment.

OEM Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT

Product Highlights

  • HT-manufactured ACC assembly in 3m (10ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
  • Fixed length and part number: 3m (10ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT
  • Cable construction: Active Breakout DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.5W (800G End)/0.6W (400G Per End)
  • Minimum bend radius: 32.5mm

Specifications

HT Part Number800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT
ManufacturerHT
Form Factor800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive Breakout DAC (ACC)
Cable Length3m (10ft)
Jacket MaterialPET
Minimum Bend Radius32.5mm
Wire AWG30AWG
Max. Power Consumption1.5W (800G End)/0.6W (400G Per End)
Modulation Format8x 100G-PAM4 to Dual 4x 100G-PMA4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA, CMIS 5.0, IEEE 802.3 ck

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PMA4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT occupies the middle of this family between 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-2M7FT at 2m (7ft) and 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-4M13FT at 4m (13ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

High-Density Rack Integration

In a densely populated rack, connector access and airflow are part of the link design. Choose the shortest length that follows the managed path comfortably, avoid tight bundles around the connector housings and preserve room for latch operation. Where power consumption is listed, include every populated interface in the host thermal budget rather than assessing a single cable in isolation. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.5W (800G End)/0.6W (400G Per End); the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.5W (800G End)/0.6W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS 5.0, IEEE 802.3 ck. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

Each assembly receives a visual connector inspection and functional link check before it is coiled and protected. Packaging is selected to avoid compressing the cable into a tight bundle, and optional rack-based labels help maintain an orderly installation when many identical interfaces are populated together. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the exact part number, length, quantity and target interface density. For multi-rack projects, list each length separately and identify any preferred carton grouping. Host model and software information can be included for a compatibility review before production or dispatch. Quantity and any labeling instructions should be attached specifically to 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT.

Generic Compatibility and Factory Testing

The assembly is evaluated for host recognition and stable link operation, with diagnostics checked where the interface provides them. This approach verifies more than electrical or optical continuity. Exact platform and firmware information remains valuable in high-density deployments because port mode and qualification policy can differ within the same connector family. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production quantities confirmed at order stage. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Singapore Fiber Optics

Fiber Optic Singapore

Singapore Service center: Singapore 567711

Factory in Asia: Shangxue Industrial Area, Shenzhen

Products Datasheet

Our full product range is available as PDF datasheets for download.

For any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our Singapore team will get back to you as soon as possible.